Comprehensive evaluation of extracellular small RNA isolation methods from serum in high throughput sequencing.
Citation | “Comprehensive Evaluation Of Extracellular Small Rna Isolation Methods From Serum In High Throughput Sequencing.”. Bmc Genomics, p. 50. . |
Center | Vanderbilt University |
Author | Yan Guo, Kasey Vickers, Yanhua Xiong, Shilin Zhao, Quanhu Sheng, Pan Zhang, Wanding Zhou, Charles R Flynn |
Abstract |
BACKGROUND: DNA and RNA fractions from whole blood, serum and plasma are increasingly popular analytes that are currently under investigation for their utility in the diagnosis and staging of disease. Small non-coding ribonucleic acids (sRNAs), specifically microRNAs (miRNAs) and their variant isoforms (isomiRs), and transfer RNA (tRNA)-derived small RNAs (tDRs) comprise a repertoire of molecules particularly promising in this regard. RESULTS: In this designed study, we compared the performance of various methods and kits for isolating circulating extracellular sRNAs (ex-sRNAs). ex-sRNAs from one healthy individual were isolated using five different isolation kits: Qiagen Circulating Nucleic Acid Kit, ThermoFisher Scientific Ambion TRIzol LS Reagent, Qiagen miRNEasy, QiaSymphony RNA extraction kit and the Exiqon MiRCURY RNA Isolation Kit. Each isolation method was repeated four times. A total of 20 small RNA sequencing (sRNAseq) libraries were constructed, sequenced and compared using a rigorous bioinformatics approach. The Circulating Nucleic Acid Kit had the greatest miRNA isolation variability, but had the lowest isolation variability for other RNA classes (isomiRs, tDRs, and other miscellaneous sRNAs (osRNA). However, the Circulating Nucleic Acid Kit consistently generated the fewest number of reads mapped to the genome, as compared to the best-performing method, Ambion TRIzol, which mapped 10% of the miRNAs, 7.2% of the tDRs and 23.1% of the osRNAs. The other methods performed intermediary, with QiaSymphony mapping 14% of the osRNAs, and miRNEasy mapping 4.6% of the tDRs and 2.9% of the miRNAs, achieving the second best kit performance rating overall. CONCLUSIONS: In summary, each isolation kit displayed different performance characteristics that could be construed as biased or advantageous, depending upon the downstream application and number of samples that require processing. |
Year of Publication |
2017
|
Journal |
BMC genomics
|
Volume |
18
|
Issue |
1
|
Number of Pages |
50
|
Date Published |
12/2017
|
ISSN Number |
1471-2164
|
DOI |
10.1186/s12864-016-3470-z
|
Alternate Journal |
BMC Genomics
|
PMID |
28061744
|
PMCID |
PMC5219650
|
Download citation |